CPIC return codes (not SAP-specific)
CM_OK | 0 |
CM_ALLOCATE_FAILURE_NO_RETRY | 1 |
CM_ALLOCATE_FAILURE_RETRY | 2 |
CM_CONVERSATION_TYPE_MISMATCH | 3 |
CM_SECURITY_NOT_VALID | 6 |
CM_SYNC_LVL_NOT_SUPPORTED_PGM | 8 |
CM_TPN_NOT_RECOGNIZED | 9 |
CM_TP_NOT_AVAILABLE_NO_RETRY | 10 |
CM_TP_NOT_AVAILABLE_RETRY | 11 |
CM_DEALLOCATED_ABEND | 17 |
CM_DEALLOCATED_NORMAL | 18 |
CM_PARAMETER_ERROR | 19 |
CM_PRODUCT_SPECIFIC_ERROR | 20 |
CM_PROGRAM_ERROR_NO_TRUNC | 21 |
CM_PROGRAM_ERROR_PURGING | 22 |
CM_PROGRAM_ERROR_TRUNC | 23 |
CM_PROGRAM_PARAMETER_CHECK | 24 |
CM_PROGRAM_STATE_CHECK | 25 |
CM_RESOURCE_FAILURE_NO_RETRY | 26 |
CM_RESOURCE_FAILURE_RETRY | 27 |
CM_UNSUCCESSFUL | 28 |
CM_OPERATION_INCOMPLETE | 35 |
CM_SYSTEM_EVENT | 36 |
Gateway error codes
CPIC_ERROR | 221 Error in the CPIC interface |
CANT_GET_MEMORY | 222 Memory bottleneck |
NI_READ_FAILED | 223 Network read error |
NI_WRITE_FAILED | 224 Network write error |
INVALID_REQUEST | 225 Invalid request |
NOT_YET_CONNECTED | 226 Not yet connected |
GW_WP_DIED | 227 Gateway process died |
SHM_READ_FAILED | 228 Shared memory problem (read) |
SHM_WRITE_FAILED | 229 Shared memory problem (write) |
NO_MORE_LU | 230 No available LU |
NO_MORE_WP | 231 No available gateway process |
CANT_START_WORKPROCESS | 232 Error when starting the gateway process |
WRONG_COMM_TYPE | 233 Wrong communication type |
CONNECT_FAILED | 234 Connection setup failed |
COMM_TABLE_ERROR | 235 Error in comm. Table |
GW_CONNECT_FAILED | 236 No connection to the gateway |
GW_DISCONNECTED | 237 Connection to the gateway disconnected |
WRITE_TO_GW_FAILED | 238 Error with GW comm. (write) |
READ_FROM_GW_FAILED | 239 Error with GW comm. (read) |
INVALID_LEN | 240 Invalid length |
INVALID_ENVIRONMENT | 241 Invalid environment |
GW_TIMEOUT | 242 Timeout |
GW_CONNECT_TO_R3 | 243 Error when setting up R/3 connection |
SYSTEM_DISCONNECTED | 244 Partner disconnected connection |
WRONG_APPCHDR_VERSION | 246 Incorrect APPC header version |
GW_APPC_SERVER_DOWN | 247 Loc. gateway not started |
TXCOM_TABLE_FAILED | 248 Error when accessing TXCOM |
COMM_TABLE_OVERFLOW | 249 Comm. table full |
C_NO_MEM | 450 No memory |
C_NO_SIDE_INFO | 451 No SIDE INFO entry |
C_TP_START | 452 TP-START failed |
C_NO_INIT | 453 No initialization |
C_GETLU | 454 “getlu” failed |
C_SIGNAL | 455 “signal” failed |
C_TIMEOUT | 456 Timeout when establishing connection |
C_ALLC | 457 CMALLC failed |
C_SEND | 458 CMSEND failed |
C_PREPARE | 459 Prepare-To-Receive failed |
C_FLUSH | 460 CMFLUS failed |
C_RECEIVE | 461 CMRCV failed |
C_NO_ARGUMENT | 462 Missing argument |
C_GET_ALLOCATE | 463 “get_allocate” failed |
C_DEAL | 464 CMDEAL failed |
C_TP_END | 465 TP-END failed |
C_MAX_CONV | 466 Max. number conv. Reached |
C_SNAOPEN | 467 “snaopen” failed |
C_SNACTL | 468 “snactl” failed |
C_NO_FLUSH | 469 No flush in IBM environment |
C_SNACLSE | 470 “snaclse” failed |
C_STATE_CHECK | 471 Status error |
C_NO_SIDE_INFO_ENTRY | 472 No side info entry |
C_NO_CONV | 473 No conversation |
C_MANUAL_CANCELD | 474 Connection manually cancelled |
C_AUTO_CANCELD | 475 Connection automatically cancelled |
C_NO_PARTNER | 476 No partner found |
C_CONFIRM | 477 Confirm failed |
C_CONFIRMED | 478 Confirmed failed |
C_NO_HOST_IN_SIDE_INFO | 479 GWHOST not in side info entry |
C_NO_SERV_IN_SIDE_INFO | 480 GWSERV not in side info entry |
C_NO_PROT_IN_SIDE_INFO | 481 PROTOCOL not in side info entry |
C_NO_LU_IN_SIDE_INFO | 482 LU not in side info entry |
C_NO_TP_IN_SIDE_INFO | 483 TP not in side info entry |
C_NO_GATEWAY_CONNECTION | 484 No connection to the gateway |
C_GETHOSTNAME | 485 gethostname failed |
C_NO_SAP_CMACCP | 486 SAP_CMACCP not executed |
C_NO_PROGRAM_NAME_ARG | 487 Program not in arg. List |
C_NO_HOST_ARG | 488 Host not in arg. List |
C_NO_SERV_ARG | 489 Service not in arg. List |
C_NO_CONVID_ARG | 490 Conv. ID not in arg. List |
C_ILLEGAL_PARAMETER | 491 Illegal parameter |
C_LU62CVCT | 492 LU62CVCT failed |
C_LU62ATTACH | 493 LU62ATTCH failed |
C_NO_CONV_TABLE | 494 No conv. Table |
C_ILL_CONV_TABLE | 495 Incorrect conv. Table |
C_ILL_MOD_VALUES | 496 Invalid conv. Modification |
C_NIHOSTTOADDR | 497 NiHostToAddr failed |
C_NIADDRTOHOST | 498 NiAddrToHost failed |
C_THOST_FAILED | 499 Reading table THOST failed |
INVALID_MODE | 630 Invalid mode number received |
MAX_NO_OF_GATEWAYS | 631 Max. no. of gateways reached |
MISSING_LU_SPEC | 632 No LU specified |
MAX_CPIC_CLIENTS | 633 Max. no. of clients reached |
BAD_TPNAME | 634 Invalid TP name |
FORK_FAILED | 635 Fork failed |
BAD_NI_HANDLE | 636 Invalid NI handle |
REXEC_FAILED | 637 rexec failed |
TP_START_FAILED | 638 Starting the TPs failed |
NI_DG_SEND_FAILED | 639 NiDgSend failed |
INTERNAL_ERROR | 640 Internal error |
GW_HOST_UNKNOWN | 664 Gateway host unknown |
GW_SERVICE_UNKNOWN | 665 Gateway service unknown |
GW_NI_ERROR | 666 NI error |
GW_EXEC_FAILED | 667 exec failed |
R2_RESTARTED | 668 R/2 restarted |
SYM_DEST_TOO_LONG | 669 Symb. destination too long |
NO_MORE_SIDE_INFO_ENTRY | 670 No more side info entries |
R3_LOGIN_FAILED | 672 R/3 Login failed |
IMS_ERROR_PURGING | 673 IMS error purging |
PENDING_TERM_OUTPUT | 674 Timeout of reg. Programs |
GW_SECURITY_ERROR | 676 TP not registered |
GW_TIMEOUT_REG_PRGM | 677 Timeout of registered program |
TP_REGISTERED | 678 TP is registered |
TP_NOTREGISTERED | 679 TP not registered |
TP_REG_SECU_ERROR | 720 Security violation for reg. Prgrms |
GW_SNC_DISABLED | 721 SNC deactivated |
GW_SNC_REQUIRED | 722 SNC required |
GW_SNC_NAME_NOT_SET | 723 SNC name not defined |
GW_SNC_NAME_NO_DEFAULT | 724 Default SNC name not permitted |
GW_SNC_PROT_NOT_SUPP | 725 Log does not support SNC |
GW_R3_NOT_CONNECTED | 726 No local R/3 system |
GW_SNC_REQUIRED_FOR_LU_TP | 727 SNC required |
CONV_ID_NOT_FOUND | 728 Conversation ID not found |
GW_SNC_SECURE_PORT | 729 Comm. must make SNC |
GW_SNC_START_EXT_DIS | 730 Start of ext. Program deactivated |
GW_SHUTDOWN | 731 Gateway was shut down |
GW_REM_PRGM_DISABLED | 732 No external programs |
GW_STOLEN_CONVID | 733 Conversation ID does not fit |
GW_NET_CONV_ERROR | 734 Net Conv Error |
GW_MONITOR_DISABLED | 735 Monitor not active |
GW_DUPLICATE_CVID | 736 Conv. ID not unique |
GW_CONNECT_TIMEOUT | 737 Timeout of connection setup to remote system |
GW_REQ_TO_DP_FAILED | 738 Request could not be transferred to the dispatcher |
GW_CLIENT_ALREADY_DISC | 739 Connection partner has already disconnected the connection |
GW_NO_HOST_IN_ROUTE | 740 No hosts contained in route |
GW_ROUTE_CONNECT_DIS | 741 Route already disconnected (no longer used) |
GW_CONN_IS_FREE | 742 Connection already released |
GW_CONN_IS_DISC | 743 Connection disconnected |
GW_REQBLK_ADM_ERROR | 744 Error in request processing |
GW_BUFINFO_ERROR | 745 Error in buffer handling |
GW_HDLINFO_ERROR | 746 Error in network handling |
TP_REG_NOREG_ERROR | 747 Number of registrations exceeded for this program |
TP_REG_ACCESS_DENIED | 748 Access to registered server denied |
GW_PARAM_NOT_FOUND | 749 Parameter could not be found |
GW_PRXY_ACCESS_DENIED | 750 Gateway must not be used as a Proxy |
GW_ACCEPT_TIMEOUT | 751 Timeout when logging on (gw/accept_timeout) |
GW_WRONG_SERVER | 752 not connected to the gateway |
C_NO_SIDE_INFO_GW | 760 No side info file |
C_RECEIVE_WITH_PAR | 761 CMRCV failed |
C_NO_SNC_LIB_ARG | 762 SNC library not in arg. List |
C_NO_SNC_NAME_ARG | 763 SNC name not in argument list |
C_SNC_INV_HANDLE | 764 SNC invalid handle |
C_SNC_DISABLED | 765 SNC deactivated |
C_SNC_ERROR | 766 General SNC error |
C_SNC_MODE_ON | 767 SNC required |
C_SNC_NOT_AVAILABLE | 768 SNC not available |
C_ILLEGAL_PARAMETER2 | 769 Invalid parameter |
C_AREA_TOO_SMALL | 770 Memory area too small |
C_SNC_INV_STATE | 771 Invalid SNC status |
C_RETURN_CODES | 772 Error numbers |
C_REG_STATE_CHECK | 773 Status violation during registration |
C_CPICTERR | 774 Error text for error number |
C_NO_SYMDEST | 775 No symbolic destination |
C_FUNCTION_NOT_SUPPORTED | 776 Function not supported |
C_NET_CONV_ERROR | 777 Conversion error when reading or writing data |
C_SIDEINFO_DISABLED | 778 Access to side info file deactivated |
C_TIMEOUT_BLOCK | 779 Timeout for blocking network call |
C_FAILOVER_ERROR | 780 Error when communicating with failover software |
C_PROXY_ERROR | 781 Error when communicating with the proxy server |
C_MPI_ERROR | 782 Error when communicating with memory pipes (Mpi) |
C_MTX_ERROR | 783 Error with lock management (mutex) |
C_CS_ERROR | 784 Error with lock management (critical section) |